Before requesting any service on your unit, please check the following points. Please note that this guide serves only as
a reference for solutions to common problems.
TROUBLESHOOTING
• Fuse blown or circuit
breaker tripped.
• Power cord unplugged.
Thermostat set too high.
• Cabinet in defrost cycle.
• Excessive amount of warn
product placed in cabinet.
• Prolonged door opening or
door ajar.
• Door gasket(s) not sealing
properly.
• Dirty condenser coil.
• Evaporator coil iced over.
• Thermostat set too warm.
• Blocking air flow.
• Excessive amount of
warm product placed in
cabinet.
• Fuse blown or circuit
breaker tripped.
• Dirty condenser coil.
• Prolonged door opening or
door ajar.
• Evaporator coil iced over.
• Loose part(s).
• Tubing vibration.
• Replace fuse or reset circuit
breaker.
• Plug in power cord.
• Set thermostat to lower
temperature.
• Wait for defrost cycle to finish.
Allow adequate time for
product to cool down.
• Ensure doors are closed when
not in use. Avoid opening doors
for long periods of time.
• Ensure gaskets are snapped in
completely. Remove gasket and
wash with soap and water. Check
condition of gasket and replace if
necessary.
• Clean the condenser coil.
• Unplug unit and allow coil to
defrost. Make sure thermostat is
not set too cold. Ensure that door
gasket(s) are sealing properly.
• Set thermostat to lower
temperature.
• Re-arrange product to allow for
proper air flow. Make sure there is
at least four inches of
clearance from evaporator.
Allow adequate time for
product to cool down.
• Replace fuse or reset circuit
breaker.
• Clean the condenser coil.
• Ensure doors are closed when not
in use. Avoid opening doors for
long periods of time.
• Locate and tighten loose
part(s).
• Ensure tubing is free from
contact with other tubing or
components.
SYMPTOM POSSIBLE CAUSE
CORRECTIVE ACTION
Compressor not running.
Condensing unit runs for
long periods of time.
Cabinet temperature is
too warm.
Cabinet is noisy.
6